IE1, nhôm, zone 22, điện áp 400V∆/690VY, chân đế, 3 temperature sensors
| 1MB1022-1AA43-4AB4 | INNOMOTICS XP motor type: 1AV1104A low-voltage motor, IEC squirrel-cage rotor, self-cooled IP65 temperature class 155(F) according to 130(B) aluminum enclosure standard efficiency IE1 2-pole frame size 100L 3 kW (50 Hz) 3.45 kW (60 Hz) Ex tc IIIB version for zone 22 with conductive dust standard color RAL 7030, if no order code is specified for selecting another color. 3 AC 50 Hz 400 VD/690 VY * 3 AC 60 Hz 460 VD IM B3 3 PTC thermistors for disconnection (2 terminals) Terminal box at top |
| 1MB1022-1BA23-4AB4 | 4 kW |
| 1MB1022-1CA03-4AB4 | 5.5 kW |
| 1MB1022-1CA13-4AB4 | 7.5 kW |
| 1MB1022-1DA23-4AB4 | 11 kW |
| 1MB1022-1DA33-4AB4 | 15 kW |
| 1MB1022-1DA43-4AB4 | 18.5 kW |
IE1, vật liệu nhôm, 4 cực (1500v/p), zone 22, điện áp 400/690, chân đế, 3 temperature sensors:
| 1MB1022-1AB43-4AB4 | INNOMOTICS XP motor type: 1AV1104A low-voltage motor, IEC squirrel-cage rotor, self-cooled IP65 temperature class 155(F) according to 130(B) aluminum enclosure standard efficiency IE1 2-pole frame size 100L 2.2 kW (50 Hz) Ex tc IIIB version for zone 22 with conductive dust standard color RAL 7030, if no order code is specified for selecting another color. 3 AC 50 Hz 400 VD/690 VY * 3 AC 60 Hz 460 VD IM B3 3 PTC thermistors for disconnection (2 terminals) Terminal box at top |
| 1MB1022-1AB53-4AB4 | 3 kW |
| 1MB1022-1BB23-4AB4 | 4 kW |
| 1MB1022-1CB03-4AB4 | 5.5 kW |
| 1MB1022-1CB23-4AB4 | 7.5 kW |
| 1MB1022-1DB23-4AB4 | 11 kW |
| 1MB1022-1DB43-4AB4 | 15 kW |
| B30 | Version additionally (or dust Ex tc - Zone 22 ™ ’4) 22) |
| B31 | Version IIC with stamping of MB |
| C02 | VIK version |
| B40 | Version for converter operation in basic version with operating data SINAMICS G120 with PM240-2. 15) |
| B41 | Version for converter operation in basic version with operating data SINAMICS S150 |
| B43 | Version for converter operation with power data on the PWM converter |
| Y68 • and converter type | Operating data such as the B40 order code with alternative SINAMICS converter on the rating plate |
| Q11 | 1 or 3 PTC thermistors - for tripping (2 terminals) |
| Q12 | 2 or 6 PTC thermistors - for alarm and tripping (4 terminals) |
| Q23 | 1 KTY84-130 temperature sensor (2 terminals) |
| Q25 | 2 KTY84-130 temperature sensors (4 terminals) |
| Q35 | 1 Pt1000 resistance thermometer (2 terminals) |
| Q36 | 2 Pt1000 resistance thermometers (4 terminals) |
| R10 | Rotation of the terminal box through 90°, entry from DE |
| R11 | Rotation of the terminal box through 90°, entry from NDE |
| R12 | Rotation of the terminal box through 180° |
| R18 | Metal cable gland, maximum configuration |
| R50 | Larger terminal box ^41 |
| N05 | Temperature class 155 (F), utilized acc. to 130 (B), coolant temperature 45 °C, derating approx. 4 % 2‘ |
| N06 | Temperature class 155 (F), utilized acc. to 130 (B), coolant temperature 50 °C, derating approx. 8 % |
| N07 | Temperature class 155 (F), utilized acc. to 130 (B), coolant temperature 55 °C, derating approx. 13 % |
| N08 | Temperature class 155 (F), utilized acc. to 130 (B), coolant temperature 60 °C, derating approx. 18 % |
| N30 | Increased air humidity/temperature with 30 to 60 g water per m3 of air |
| N31 | Increased air humidity/temperature with 60 to 100 g water per m3 of air |
| Y50 • CT.. °Cor IA .... m above sea level | Temperature class 155 (F), utilized acc. to 130 (B), with higher coolant temperature and/or installation altitude |
| S00 | Unpainted (only cast-iron parts primed) |
| S01 | Unpainted, only primed |
| S02 | Special paint finish C3 |
| S03 | Special paint finish sea air resistant C4 |
| S06 | Top coat polyurethane |
| Y53 • and paint finish RAL.... | Paint finish in other standard RAL colors: RAL 1015, 5002, 5009, 5010, 5012, 5015,6011,7001,7011,7016, 7031, 7032, 7035, 7037, 8012, 9005 (see Catalog Section 1 "Introduction") |
| Y56 • and paint finish RAI_____ | Paint finish in special RAL colors: For RAL colors, see "Special paint finish in special RAL colors" (see Catalog Section 1 "Introduction") |
| Y66 • und Anstrich | Non-standard colors Colors see "Paint finish in non-standard colors (see Catalog Section 1 "Introduction") |
| F70 | Mounting of separately driven fan 17) |
| G30 | Mounting of LL841 (FITL); 1024 I explosion-protected rotary pulse encoder |
| F77 | Low-noise version for 2-pole motors with clockwise direction of rotation |
| F78 | Low-noise version for 2-pole motors with counterclockwise direction of rotation |
| G43 | Mechanical protection for encoder |
| H00 | Protective cover |
| H01 | Screwed-on (instead of cast) feet |
| H02 | Vibration-proof version; vibration resistance to Class 3M4 according to IEC 60721-3-3:1994 |
| H03 | Condensation drainage holes e) |
| H07 | Rust-resistant screws (externally) |
| H19 | IP66 degree of protection |
| H20 | IP65 degree of protection 4) |
| H22 | IP56 degree of protection b) |
| H23 | Drive-end seal for flange-mounting motors, oil-tight to 0.1 bar3* |
| D03 | Coolant temperature -40 to +40 °C 20) |
| D22 | Motor without CE marking for export outside EEA (see EU Regulation 640/2009) |
| D23 | Motor exclusively according to the Energy-related Products Law, Article 1 dated 27.2.2008, motor to be used in means of transport for persons and goods |
| D32 | Ex certification for China |
| D34 | China Energy Efficiency Label |
| D35 | EAC Ex certificate for the Eurasian Customs Union 18^ |
| D37 | lECEx certification |
| D70 | MEPS Australia |
| L20 | Located bearing DE |
| L21 | Located bearing NDE |
| L22 | Bearing design for increased cantilever forces '3‘ |
| L23 | Regreasing device |
| L25 | Bearings reinforced at both ends for DE and NDE, bearing size 63 |
| L51 | Bearing insulation NDE |
| Q01 | Measuring nipple for SPM shock pulse measurement for bearing inspection |
| L00 | Vibration severity grade B la) |
| L01 | Balancing without feather key |
| L02 | Full-key balancing |
| L04 | Shaft extension with standard dimensions, without feather keyway |
| L05 | Standard, cylindrical shaft extensicn (second shaft extension) NDE acc. to EN 50347 |
| L06 | Standard shaft made of stainless steel (e.g. 1.4021) |
| L07 | Shaft extension run-out in accordance with IEC 60072-1 precision class |
| L08 | Shaft extension run-out, concentricity and perpendicularity in accordance with IEC 60072-1 precision class for flange-mounted motors |
| Y58 • and customer specifica- tions | Non-standard cylindrical shaft extension, DE 7> |
| Y59 • and customer specifica- tions | Non-standard cylindrical shaft extension, NDE7' |
| F76 | Metal external fan 8) |
| Q02 | Anti-condensation heating for 230 V (2 terminals) 9^ |
| Q03 | Anti-condensation heating for 115 V (2 terminals) 9^ |
| M10 | Second rating plate, loose |
| M11 | Rating plate, stainless steel |
| Y80 • and customer specifica- tions | Additional rating plate with deviating rating plate data |
| Y82 • and customer specifica- tions | Additional rating plate with customer specifications |
| Y84 • and customer specifica- tions | Additional information on rating plate and on package label (max. 20 characters) |
| B02 | Inspection certificate 3.1 according to EN 10204 1D> |
| B60 | Document - Electrical datasheet |
| B61 | Document - Order dimensional drawing |
| B83 | Type test with heat run for horizontal motors, with acceptance |
| B90 | "Basic" documentation package |
| B91 | "Advanced" documentation package |
| B92 | "Projects" documentation package |
| B99 | Wire-lattice pallet packaging |
| M01 | Connected in star for dispatch |
| M02 | Connected in delta for dispatch |
| L21 | Located bearing NDE 11J |
| L22 | Bearin^tjJ^sign for increased cantilever forces |
| L25 | Bearings reinforced at both ends for DE and NDE, bearing size 63 |
| L30 | Drainage for used grease |
| L37 | Special version with higher speeds |
| L50 | Bearing insulation DE 211 |
| L51 | Bearing insulation NDE 21) |
| Q01 | Measuring nipple for SPM shock pulse measurement for bearing inspection |
| LOO | Vibration severity grade B |
| L01 | Balancing without feather key1B) |
| L02 | Full-key balancing 1B) |
| L04 | Shaft extension with standard dimensions, without feather keyway |
| L05 | Standard, cylindrical shaft extension (second shaft extension) NDE acc. to EN 50347 |
| L06 | Standard shaft made of stainless steel (e.g. 1.4021) |
| L07 | Shaft extension run-out in accordance with IEC 60072-1 precision class |
| L00 | Shaft extension run-out, concentricity and perpendicularity in accordance with IEC 60072-1 precision class for flange-mounted motors |
| Y58 • and customer specifications | Non-standard cylindrical shaft extension, DE w |
| Y59 • and customer specifications | Non-standard cylindrical shaft extension, NDE 3) |
| Y60 • and customer specifications | Special shaft steel |
| F68 | Metal fan made of brass |
| F90 | Without external fan and without fan cover |
| Q02 | Anti-condensation heating for 230 V (2 terminals) |
| Q03 | Anti-condensation heating for 115 V (2 terminals) |
| Q06 | Anti-condensation heating for 400 V (2 terminals) |
| Y81 • and customer specifications | Separately driven fan with non-standard voltage and/or frequency |
| M10 | Second rating plate, loose |
| Y80 • and customer specifications | Additional rating plate with deviating rating plate data18' |
| Y82 • and customer specifications | Additional rating plate with customer specifications |
| Y84 • and customer specifications | Additional information on rating plate and on package label (max. 20 characters) |
| Y85 • und Besteller-angabe | Adhesive label, supplied loose (printed with: Article No., Serial No.: 2 lines of text) |
| Q80 | Extension of the liability for defects by 12 months to a total of 24 months (2 years) from delivery 4>2S> |
| Q81 | Extension of the liability for defects by 18 months to a total of 30 months (2.5 years) from delivery 4> |
| Q82 | Extension of the liability for defects by 24 months to a total of 36 months (3 years) from delivery A> |
| Q83 | Extension of the liability for defects by 30 months to a total of 42 months (3.5 years) from delivery 4> |
| Q84 | Extension of the liability for defects by 36 months to a total of 48 months (4 years) from delivery 4> |
| Q85 | Extension of the liability for defects by 48 months to a total of 60 months (5 years) from delivery 4> |
| B02 | Inspection certificate 3.1 according to EN 10204 4' |
| B51 | Equivalent circuit diagram |
| B52 | Starting diagram (torque vs. speed and current vs. speed) |
| B60 | Document - Electrical datasheet |
| B61 | Document - Order dimensional drawing |
| B65 | Standard test (routine test) with acceptance |
| B67 | Temperature test without acceptance |
| B68 | Temperature test with acceptance |
| B82 | Type test with heat run for horizontal motors, without acceptance |
| B83 | Type test with heat run for horizontal motors, with acceptance |
| B90 | "Basic" documentation package |
| B91 | "Advanced" documentation package |
| B92 | "Projects" documentation package |
| M01 | Connected in star for dispatch |
| M02 | Connected in delta for dispatch |